Tactile 3D coordinate metrology
The reference method for regular geometry and the tightest tolerances. Measured in the temperature-controlled measuring room at reference temperature per ISO 1, or on your machine.
The reference method for regular geometry and the tightest tolerances. Measured in the temperature-controlled measuring room at reference temperature per ISO 1, or on your machine.
Probed by contact, point by point or scanning. For tolerances and datum systems that demand the highest confidence.
Expanded measurement uncertainty U with a coverage factor of k = 2, evaluated with a calibrated workpiece to ISO 15530-3 and assessed to the GUM (ISO/IEC Guide 98-3). The coverage interval is roughly 95 percent. The number of stylus positions is stated because each position is qualified separately and adds its own uncertainty to the result. With several positions the uncertainty is therefore usually higher than with one. All values are rounded up to 0.5 µm.
Stated in micrometres. The measurement report gives the same figures in millimetres, where 2.5 µm appears as 0.002 5 mm. Where a measurement task calls for its own uncertainty budget, we calculate it for that task and state the result separately in the report. All measurements run in the temperature-controlled measuring room at the reference temperature of ISO 1. How the room is built and monitored is described on the measuring laboratory page.
Regular geometry with the tightest tolerances? Quotes are effort-based and transparent.